A novel sideways fall simulator to study hip fractures ex vivo.
A novel sideways fall simulator to study hip fractures ex vivo.
Blog Article
Falls to the side are the leading cause of hip fractures in licorice caramel creams the elderly.The load that a person experiences during a fall cannot be measured with volunteers for ethical reasons.To evaluate injurious loads, while considering relevant energy input and body posture for a sideways fall, a subject-specific cadaveric impact experiment was developed.
Full cadaveric femur-pelvis constructs (N = 2) were embedded in surrogate soft tissue material and attached to metallic surrogate lower limbs.The specimens were then subjected to an inverted pendulum motion, simulating a fall to the side with an impact to the greater trochanter.The load at the ground and the deformation of the pelvis were evaluated using a 6-axis force transducer and two high-speed cameras.
Post-test, a trauma surgeon (PG) evaluated specimen injuries.Peak ground contact forces were 7132 merits battery charger N and 5641 N for the fractured and non-fractured specimen, respectively.We observed a cervical fracture of the femur in one specimen and no injuries in a second specimen, showing that the developed protocol can be used to differentiate between specimens at high and low fracture risk.